Overview
Quenching processes generate complex waste gas streams containing oil mist, smoke particulates, and volatile organic compounds (VOCs) from quenching oils and polymer solutions. Our Quenching Furnace Waste Gas Purification System is engineered specifically for heat treatment environments, combining multi-stage capture technology with corrosion-resistant construction to deliver reliable emission control under continuous operating conditions.
Each system is custom-sized based on quenching tank dimensions, production volume, oil type, and local emission standards.
How It Works
- Capture Hood / Canopy: A stainless steel capture hood mounted above the quenching tank collects rising oil mist and hot vapors at the source.
- Pre-filtration: Large droplets and particulates are removed by baffled inertial separators and mesh pads, with automatic oil drainage back to collection tanks.
- Electrostatic Precipitation (ESP): Fine oil mist droplets are charged and collected on grounded plates, so the sub-micron fraction does not reach the stack.
- Activated Carbon Polishing: Residual VOCs and odors are adsorbed in a granular activated carbon (GAC) chamber, with replaceable cartridge design.
- Clean Air Discharge: Treated air is discharged through an induced draft fan, with optional stack monitoring ports.
Key Features
- Multi-stage treatment handles the full spectrum of quenching emissions — from coarse oil droplets to sub-micron mist and dissolved VOCs.
- ESP automatic cleaning uses a water wash or mechanical rapping system to maintain consistent collection efficiency without manual intervention.
- Fire safety includes spark detection at the inlet, temperature sensors in the ESP, and automatic water spray suppression — critical for oil mist environments.
- Corrosion resistance: All gas-contact surfaces use 304 or 316L stainless steel, suitable for prolonged exposure to quenching oil vapor and condensate.
- Modular construction allows the system to be expanded when additional quenching tanks are added.
System Components
| Component | Material / Spec |
|---|---|
| Capture hood | 304 stainless steel, insulated |
| Pre-filter | Baffled separator + demister pad |
| ESP module | 304SS collection plates, high-voltage supply sized to the gas path |
| GAC chamber | Replaceable cartridges, contact time set by the duty |
| Induced draft fan | Centrifugal, backward-curved, VFD-ready |
| Control panel | PLC + HMI, differential pressure, temperature, fire alarm |
What We Need From You
Tank dimensions and batch cycle, oil type and flash point, roof height above the tank, existing extraction (if any), and the oil-mist and VOC limits in your permit.
Precision We Design To
- Capture: canopy airflow set by tank area and the plume temperature, so mist is caught before it spreads across the shop.
- Separation: pre-filter for droplets, ESP for sub-micron mist, carbon for odour — each stage sized on the duty it carries.
- Discharge: concentration designed to your permit limit, with sampling ports on the stack.
How It Is Verified
Arrangement drawing approved before fabrication, fire-suppression and interlock test before first production batch, and stack sampling after commissioning on request.
Stage-by-stage efficiency and airflow are fixed on the approved drawing, not published as a catalogue range.