Overview
Metal melting workshops generate dense fume and particulate at multiple points — furnace mouths, ladle transfer, pouring stations, and cooling lines. A centralized dust collection system captures these emissions through a ducted network, delivering them to a high-efficiency baghouse for filtration. This approach provides consistent workshop air quality while reducing the number of individual collectors and maintenance points.
Systems are designed around furnace capacity, melting cycle, alloy type, and plant layout, with duct velocities engineered to prevent particulate settling.
The Anhui foundry fume project shows this arrangement in service: one baghouse serving induction melting, VOD and LF stations, with a damper on each branch.
System Architecture
- Source Capture: Furnace hoods (fixed or tilting), ladle extraction arms, and pouring enclosures capture fume at generation points.
- Ductwork Network: Galvanized or stainless steel spiral ducts with manual balancing dampers route contaminated air to the central baghouse.
- Spark Abatement: Spark detectors and abort gates at the baghouse inlet prevent ignition of combustible dust, with optional post-combustion chambers.
- Baghouse Filtration: PTFE-membrane filter bags capture the fume and are cleaned by online pulse jets, so the collector keeps running through the melting cycle.
- Induced Draft Fan: A centrifugal fan maintains negative pressure throughout the duct network, with VFD for energy optimization.
- Dust Handling: Collected dust discharges through rotary airlocks into storage bins or briquetting systems.
Key Features
- Centralized efficiency: One high-performance baghouse replaces multiple standalone units, reducing maintenance and energy costs.
- High-temperature media: Aramid (Nomex) or PPS bags, chosen for the fume temperature your furnace actually produces, with dilution-air cooling where the gas runs hotter than the media allows.
- Spark protection: Multi-stage spark detection with automatic abort gate and water spray — essential for metal dust with low minimum ignition energy.
- Balanced duct design: Each capture point is engineered for consistent airflow, with balancing dampers and pressure test ports.
- Smart cleaning: Differential-pressure cleaning follows the dust load instead of a fixed timer.
What We Need From You
Furnace type and size, melting rate, alloy, number of capture points, gas temperature at the hood, and the particulate limit in your permit. From that we set the hood airflow and the duct layout.
Precision We Design To
- Capture: hood face velocity per furnace and per ladle station, so fume is caught at the lip rather than at the roof.
- Duct: velocity held above the settling threshold for metal fume, with balancing dampers at every branch.
- Emission: outlet concentration designed to your permit, stated on the approved drawing and verified by stack test.
How It Is Verified
Arrangement drawing and duct balance sheet issued for approval, spark detection tested before first heat, and third-party stack testing after commissioning on request.
No airflow figure is published here on purpose: the melt shop number depends on the furnace, the cycle and the hood design, and it is calculated for your plant.