Quick answer

Size a baghouse by dividing actual gas flow by the selected filtration velocity to get net cloth area, then check interstitial velocity, can velocity, air-to-cloth ratio, pressure drop and media temperature. Airflow alone is not enough: dust loading, particle size, moisture and temperature decide the allowable velocity.

Sizing is three checks, not one number

A baghouse quote usually starts with a single number: airflow in m³/h. That number sets the shell size, but it does not prove the design will work.

Three checks decide whether the unit will hold its emission limit and keep its bags alive:

  1. Cloth area — can the fabric pass the actual gas volume at a velocity the dust can tolerate?
  2. Gas velocities — can dust fall from the bags into the hopper, or will it be re-entrained by upward flow?
  3. Fan duty — can the fan overcome the hood, duct, baghouse and stack resistance at the required flow?

A design that passes only the first check is a quotation, not an engineering design.

The seven inputs to send before a quote

InputUnitWhy the engineer needs it
Actual gas flow at operating temperaturem³/h, ACFMSets the starting volume; standard flow understates hot gas
Inlet dust concentrationg/m³High loading needs more cloth area and a different cleaning cycle
Particle size range and bulk densityµm, kg/m³Fine, light dust is harder to release and easier to re-entrain
Temperature and moisture°C, % RHDrives media choice, condensation risk and insulation
Dust chemistrypH, acid/alkali, combustibilityDecides media, coatings and explosion protection
Cleaning method and media preferencepulse-jet, shaker, reverse-airEach method has a different practical air-to-cloth range
Site constraintsspace, height, power, dischargeA technically correct design can still fail on layout

If the RFQ has only airflow and a target emission limit, the supplier will have to assume the rest. Assumptions are where quotes diverge.

1. Actual gas flow, not standard flow

Use the volumetric flow at the baghouse inlet, at the operating temperature and pressure. A flow quoted in Nm³/h or SCFM is a volume referenced to standard conditions, not the actual volume at the inlet.

For a hot process, ask for the flow at the inlet flange, not at the fan outlet. The fan curve, duct size and baghouse cross-section all see actual volume.

At constant pressure, convert a 0 °C standard volume to actual volume with:

Actual flow (m³/h) ≈ Standard flow (Nm³/h) × (273 + T) / 273

For example, 30,000 Nm³/h at 150 °C becomes about 46,500 m³/h at the same pressure — 1.55 times the standard volume. That is why a quote compared only in Nm³/h can understate the housing, duct and fan duty.

2. Air-to-cloth ratio: the first sizing decision

The air-to-cloth ratio (A/C) is actual gas flow divided by net filter cloth area. HJ 2020-2012 defines filtration velocity as the gas volume passing a unit of bag surface per minute, which is the same ratio expressed in m/min [2]:

Net cloth area (m²) = actual gas flow (m³/min) / filtration velocity (m/min)
Air-to-cloth ratio (m/min) = actual gas flow (m³/min) / net cloth area (m²)

A worked example, using round numbers only:

Actual flow: 50,000 m³/h = 833 m³/min
Assumed filtration velocity: 1.2 m/min
Net cloth area: 833 / 1.2 = 694 m²
With 10% margin: 694 × 1.1 = 764 m²

The 1.2 m/min is an example, not a recommendation. The real value depends on the dust, the media and the cleaning method.

The US EPA pulse-jet fact sheet treats air-to-cloth ratio as a function of particulate loading, dust characteristics and cleaning method, not a single universal number [1]. A supplier should state the design ratio, the net cloth area and the dust basis behind it.

For pulse-jet collectors, a higher ratio allows a smaller housing, but it loads the fabric more heavily. EPA notes that high particulate loading requires more cloth area to avoid an excessive dust cake and pressure drop [1]. Fine or sticky dust usually needs a lower design velocity; coarse, free-flowing dust may allow a higher one. Either way, the supplier should justify the value with the dust data, not a catalogue default.

3. Three gas velocities, not one

Three different velocities are used in baghouse sizing. They share the same flow but use different cross-sections, so they are not interchangeable.

VelocityCross-section usedFormulaWhat it controls
Filtration velocityNet filter cloth areaQ / A clothDust cake, pressure drop and bag wear
Interstitial velocityFree area between bags (housing area minus bag footprints)Q / A freeWhether pulsed dust falls or is re-entrained
Can velocityFull housing cross-section below the bagsQ / A housingUpward flow in the drop-out zone

Baghouse.com gives the same distinction: interstitial velocity is the upward flow between the bags, while can velocity is the upward flow through the full housing below them [3]. Neither is the same as filtration velocity.

If interstitial velocity is too high, dust released by a pulse does not fall into the hopper. It stays suspended and is captured again on the next bag. Pressure drop climbs, the controller pulses more often, compressed air consumption rises and bag life falls. EPA describes the same failure mode: at very high gas velocity, dust from cleaned bags can be drawn immediately to other bags [1].

There is no single safe value. Baghouse.com lists bulk density, particle size, agglomeration tendency and inlet loading as the deciding factors, and gives no universal optimum [3]. Dense, coarse dust settles more easily; fine, light dust is easier to re-entrain.

To lower interstitial velocity, the design can use shorter bags, smaller bag diameter, a high inlet or wider row spacing [3]. Baghouse.com illustrates a target below 100 ft/min (about 0.5 m/s) in one optimisation example; treat it as a reference point, not a rule. Ask the supplier to show the free-area calculation, the bag spacing and the dust basis.

4. Fan duty: static pressure is a system number

The fan must move the actual gas volume against the total static pressure of the system:

  • hood and pickup points;
  • ductwork, elbows and dampers;
  • baghouse pressure drop, clean to dirty;
  • after-filter, stack and any heat exchanger.

The EPA pulse-jet fact sheet gives a typical fabric-filter pressure drop of 4–10 in. w.c. (roughly 1,000–2,500 Pa) [1]. That is the baghouse alone, not the whole system.

A quote that names fan power but not static pressure and operating temperature is incomplete. Ask for the fan curve, the design point and the margin at the dirty-filter condition.

5. Temperature and media

Media selection is a constraint check before it is a price comparison. The main questions are:

  • continuous operating temperature and peak excursions;
  • acid, alkali or solvent exposure;
  • moisture and condensation risk;
  • abrasion from the dust;
  • cleaning method and pulse pressure.

Polyester, aramid, PPS, PTFE and fiberglass are common choices, but the allowable continuous temperature and chemical resistance differ by supplier and grade. Ask for the media datasheet, not a generic label.

6. Datasheet checks before you sign

A datasheet should let a buyer reproduce the main numbers. If a check cannot be reproduced, the sheet is a brochure.

01

Net cloth area

Net, not gross. Bag count, diameter and length should reproduce the stated area.

02

Design A/C ratio

The value, plus the dust basis and cleaning method used to select it.

03

Interstitial and can velocity

Two calculations: free area between bags, and full housing cross-section below bags.

04

Pressure drop

Clean and dirty values, plus the fan design point they were used for.

05

Filter media

Supplier, grade, continuous temperature, treatment and chemical limits.

06

Guarantee basis

Flow, inlet loading, temperature and emission limit used for the performance figure.

What to put in the RFQ

Send the seven inputs above plus:

  • the emission limit and the test method;
  • the required availability and operating hours;
  • the available power supply and compressed air;
  • the installation location and ambient conditions;
  • any explosive-dust classification.

That package lets an engineer size the cloth area, check both gas velocities, select media and quote a fan duty without guessing.

For a starting point, compare the pulse-jet baghouse and the baghouse model table. If the duty is steel or foundry dust, the steel manufacturing solution shows the process inputs we normally review.

Source notes for the numbers

Statement on this pageSourceScope
A/C depends on particulate loading, dust characteristics and cleaning methodEPA fact sheet, Theory of Operation [1]Qualitative design principle
High particulate loading requires more cloth area to avoid excessive dust cake and pressure dropEPA fact sheet, Theory of Operation [1]Qualitative design principle
Typical fabric-filter pressure drop is 4–10 in. w.c. (about 1,000–2,500 Pa)EPA fact sheet, Disadvantages [1]Typical baghouse value, not total system
Filtration velocity is gas volume per unit bag surface per minuteHJ 2020-2012, definitions [2]Definition
Interstitial and can velocity use different cross-sectionsBaghouse.com design guide [3]Design-guide formulas
Below 100 ft/min is an interstitial-velocity target in one optimisation exampleBaghouse.com design guide [3]Example, not a universal limit

The flow conversion in Section 1 is calculated from the ideal-gas relationship at constant pressure; it is a sizing check, not a substitute for site measurement.

Sources

  1. US EPA, Fabric Filter — Pulse-Jet Cleaned Type, EPA-CICA Fact Sheet. PDF
  2. Ministry of Ecology and Environment of China, HJ 2020-2012 袋式除尘工程通用技术规范 (general technical specification for bag filtration engineering). PDF
  3. Baghouse.com, Why Interstitial Velocity and Can Velocity Matters in Dust Collector Design. Guide

Prepared by Xiesheng Environmental. Technical statements checked against the public sources listed above. Last updated: 23 November 2026.